| 14 | The '''peptide stability table''' collects reported storage conditions and stability intervals for compounds covered on this wiki. It is a navigational and comparative aid rather than a source in its own right: every figure in it is attributable to labelling or to a published study, and the two are not equivalent evidence. | 15 | The '''peptide stability table''' collects reported storage conditions and stability intervals for compounds covered on this wiki. It is a navigational and comparative aid rather than a source in its own right: every figure in it is attributable to labelling or to a published study, and the two are not equivalent evidence. |
| ⋮ | ⋮ | ||
| 29 | 30 | ||
| 30 | {{note|An interval is not a cliff. A 28-day figure means the formulation was shown to remain within specification for 28 days under the stated conditions; it does not mean the material is inert on day 27 and unusable on day 29, nor that it was ever tested on day 40.}} | 31 | {{note|An interval is not a cliff. A 28-day figure means the formulation was shown to remain within specification for 28 days under the stated conditions; it does not mean the material is inert on day 27 and unusable on day 29, nor that it was ever tested on day 40.}} |
| + | 32 | ||
| + | 33 | == Why cross-source comparison is unsafe == | |
| + | 34 | Four differences between sources make two stability figures incomparable even when both are honestly reported. | |
| + | 35 | ||
| + | 36 | '''The specification differs.''' "Stable for 28 days" means "remained within the specification" and specifications differ. A limit of 95% of label potency and a limit of 90% produce different intervals from identical data. | |
| + | 37 | ||
| + | 38 | '''The assay differs.''' A stability-indicating [[High-performance liquid chromatography|HPLC]] method that resolves the principal degradant reports loss that a method which co-elutes it does not. [[Analytical method validation|Method validation]] is what establishes that a method is stability-indicating, and research-compound figures rarely state whether it was.{{r|ich}} | |
| 31 | 39 | ||