126* '''Extended plunger tip.''' The plunger tip carries a projection that enters the hub. Values are intermediate and depend on the fit achieved.126* '''Extended plunger tip.''' The plunger tip carries a projection that enters the hub. Values are intermediate and depend on the fit achieved.
127127
+128Trade-offs are documented. Permanently attached needles cannot be exchanged between withdrawal and injection, which is inconvenient when a wide-bore needle is wanted for withdrawal from a stoppered vial and a fine one for injection. Fine permanently attached needles are also slower to draw viscous liquids and are more easily bent or blunted by passage through an elastomeric closure, a route by which [[Multi-dose vial|stopper coring]] becomes more likely.{{r|who2015}}
+129
128== Measurement and standards ==130== Measurement and standards ==
129Dead space is not itself a specified parameter in the principal device standards. ISO 7886-1 specifies the graduated capacity, the tolerance on delivered volume, dimensional requirements, freedom from leakage and the force required to operate the plunger; ISO 8537 does the equivalent for insulin syringes; ISO 7864 covers needles and ISO 9626 the stainless-steel tubing from which they are made. None sets a maximum retained volume, and none requires it to be declared.{{r|iso7886,iso8537,iso7864,iso9626}}131Dead space is not itself a specified parameter in the principal device standards. ISO 7886-1 specifies the graduated capacity, the tolerance on delivered volume, dimensional requirements, freedom from leakage and the force required to operate the plunger; ISO 8537 does the equivalent for insulin syringes; ISO 7864 covers needles and ISO 9626 the stainless-steel tubing from which they are made. None sets a maximum retained volume, and none requires it to be declared.{{r|iso7886,iso8537,iso7864,iso9626}}
146<ref name="ppdeadspace">PeptidePedia community device-measurement tally, 2026 (self-reported, uncalibrated balances, protocol not controlled; weak evidence — see [[Project:Sourcing_guidelines]]).</ref>148<ref name="ppdeadspace">PeptidePedia community device-measurement tally, 2026 (self-reported, uncalibrated balances, protocol not controlled; weak evidence — see [[Project:Sourcing_guidelines]]).</ref>
147149
+150== Further reading ==
+151* World Health Organization and UNAIDS. ''Technical Brief: Low Dead Space Syringes'' — the public-health framing of the parameter.
+152* Frid AH, Kreugel G, Grassi G, et al. "New insulin delivery recommendations." ''Mayo Clinic Proceedings'' 91(9):1231–1255 (2016) — needle length and technique, with dead space treated in passing.
+153