| 116 | For lyophilised material the picture reverses. A dry cake has no ice to form and no interface to create, and freezing a sealed lyophilised vial is generally regarded as harmless — which is why frozen storage is the recommended long-term condition for dry peptide while being contraindicated for the same peptide in solution.{{r|ich_q1a}} | 116 | For lyophilised material the picture reverses. A dry cake has no ice to form and no interface to create, and freezing a sealed lyophilised vial is generally regarded as harmless — which is why frozen storage is the recommended long-term condition for dry peptide while being contraindicated for the same peptide in solution.{{r|ich_q1a}} |
| 117 | 117 | ||
| + | 118 | == Assessment and disposition == | |
| + | 119 | Disposition of a product after an excursion follows a defined sequence, and its output is a documented decision rather than a measurement. | |
| + | 120 | ||
| + | 121 | # The record is retrieved, its instrument's calibration status confirmed, and the profile reconstructed with custody points identified. | |
| + | 122 | # The exposure is characterised: maximum and minimum reached, duration outside the labelled range, mean kinetic temperature over the relevant period, and whether any threshold such as freezing was crossed. | |
| + | 123 | # The exposure is charged against the product's stability budget, cumulatively with any previous excursions recorded for that consignment. | |
| + | 124 | # The manufacturer's stability data are consulted, including accelerated and stress data, to establish whether the exposure lies within a range for which behaviour is known. | |
| + | 125 | # Where the exposure falls outside what the data support, confirmatory testing is performed on a sample, using methods capable of detecting the degradation expected. | |
| + | 126 | # A disposition is recorded: release unchanged, release with shortened dating, quarantine pending further data, or rejection.{{r|whotrs961,eugdp2013}} | |
| + | 127 | ||
| 118 | == References == | 128 | == References == |