91* For a smaller intended dose of 0.05 mL, the same 0.070 mL dead space exceeds the dose entirely; no plunger position can deliver 0.05 mL if that volume of air must first be displaced from the hub.91* For a smaller intended dose of 0.05 mL, the same 0.070 mL dead space exceeds the dose entirely; no plunger position can deliver 0.05 mL if that volume of air must first be displaced from the hub.
9292
+93The vial-yield arithmetic follows from the wastage figure. Each dose consumes 0.20 mL delivered plus 0.070 mL retained, or 0.270 mL. From 2.00 mL, seven full doses can be drawn (7 × 0.270 = 1.89 mL), with 0.11 mL remaining — insufficient for an eighth. The nominal ten doses have become seven, a 30% reduction. With a fixed-needle insulin syringe at 0.005 mL, each dose consumes 0.205 mL and nine full doses can be drawn, with 0.155 mL remaining.{{r|ppdeadspace}}
+94
+95=== Priming and air management ===
+96The mechanism by which the dose error arises is the presence of gas where liquid is assumed. Descriptions of injection technique in manufacturers' [[Prescribing information|prescribing information]] and in nursing references accordingly treat expulsion of air before the dose is measured as a defined step, and treat the graduation as valid only for a gas-free barrel and hub.{{r|who2015}}
+97
+98Two configurations make the error more likely. A detachable needle attached after the barrel has been filled introduces a hub full of air that must then be displaced. Reconstitution performed with one needle and injection with another — a common arrangement, since a wider gauge is easier to use for withdrawal — reintroduces an air-filled hub at the point of exchange. Neither is inherently unsafe, but both place the burden of correctness on a step that is easy to omit and whose omission is not visible afterwards.{{r|strauss2006}}
+99
93== References ==100== References ==
94{{reflist}}101{{reflist}}
96<ref name="zule2013">Zule WA, Cross HE, Stover J, Pretorius C. "Are major reductions in new HIV infections possible with people who inject drugs? The case for low dead-space syringes in highly affected countries." ''International Journal of Drug Policy'' 24(1):1–7 (2013).</ref>103<ref name="zule2013">Zule WA, Cross HE, Stover J, Pretorius C. "Are major reductions in new HIV infections possible with people who inject drugs? The case for low dead-space syringes in highly affected countries." ''International Journal of Drug Policy'' 24(1):1–7 (2013).</ref>
97<ref name="strauss2006">Strauss K, van Zundert A, Frid A, Costigliola V. "Pandemic influenza preparedness: the critical role of the syringe." ''Vaccine'' 24(24):4874–4882 (2006).</ref>104<ref name="strauss2006">Strauss K, van Zundert A, Frid A, Costigliola V. "Pandemic influenza preparedness: the critical role of the syringe." ''Vaccine'' 24(24):4874–4882 (2006).</ref>
+105<ref name="who2015">World Health Organization. ''WHO Guideline on the Use of Safety-Engineered Syringes for Intramuscular, Intradermal and Subcutaneous Injections in Health Care Settings''. Geneva (2015).</ref>
98<ref name="iso7886">ISO 7886-1:2017, ''Sterile hypodermic syringes for single use — Part 1: Syringes for manual use''. International Organization for Standardization.</ref>106<ref name="iso7886">ISO 7886-1:2017, ''Sterile hypodermic syringes for single use — Part 1: Syringes for manual use''. International Organization for Standardization.</ref>
99<ref name="iso7864">ISO 7864:2016, ''Sterile hypodermic needles for single use — Requirements and test methods''. International Organization for Standardization.</ref>107<ref name="iso7864">ISO 7864:2016, ''Sterile hypodermic needles for single use — Requirements and test methods''. International Organization for Standardization.</ref>