Contributions of ResolutionRoo
User contributions·24 logged edits·page 1 of 1
Contributions by ResolutionRoo, newest first. This list covers edits recorded in the site's change log; the editor's lifetime total of 1,866 edits includes activity predating the current log.
- 18:01, 13 Jun 2026 (diff | hist) FLOW trial 4,583 ±0 state the analysis population: intention-to-treat or per-protocol
- 15:10, 6 Jun 2026 (diff | hist) Limit of detection 4,865 ±0 m rm the assertion that two laboratories must agree; they need not
- 11:00, 10 Apr 2026 (diff | hist) Talk:Analytical method validation 537 +170 /* Robustness and inter-laboratory disagreement */ new section
- 10:40, 13 Mar 2026 (diff | hist) Talk:High-performance liquid chromatography 537 +247 /* Orthogonal method paragraph */ new section
- 13:15, 10 Feb 2026 (diff | hist) Talk:Reverse-phase HPLC 611 +200 /* Gradient duration as the dominant variable */ reply
- 07:57, 22 Jan 2026 (diff | hist) Retention time 4,104 ±0 correct the resolution formula — the denominator is the sum of the widths
- 16:58, 4 Nov 2025 (diff | hist) Analytical method validation 5,342 ±0 clarify that area percent is not mass percent
- 04:46, 11 Oct 2025 (diff | hist) CagriSema 5,687 ±0 give the isoelectric point with the method it was determined by
- 12:23, 7 Aug 2025 (diff | hist) USP General Chapter 71 4,070 ±0 add the sample preparation, since the result depends on it
- 15:56, 4 Aug 2025 (diff | hist) Liquid chromatography-mass spectrometry 4,276 ±0 m fix indentation in the source
- 11:34, 2 Jul 2025 (diff | hist) Reconstitution calculator 7,641 +336 give the figures to a consistent number of significant figures
- 19:39, 18 Jun 2025 (diff | hist) Deamidation 4,219 ±0 add the repeatability figure with the number of injections
- 17:42, 7 Jun 2025 (diff | hist) Body composition assessment 4,416 ±0 fix indentation in the source
- 14:11, 7 Jun 2025 (diff | hist) Sterility testing 3,663 +27 add the ionisation mode to the mass-spectrometry description
- 21:02, 2 May 2025 (diff | hist) Fasting insulin 3,216 ±0 expand §Standardisation
- 17:42, 12 Mar 2025 (diff | hist) Contract development and manufacturing organisation 3,584 +122 ce, tighten prose
- 12:33, 12 Mar 2025 (diff | hist) Bacterial endotoxin test 4,398 ±0 correct the flow rate — the source gives it in mL/min
- 00:44, 6 Mar 2025 (diff | hist) High-performance liquid chromatography 5,364 ±0 clarify that mass spectrometry confirms identity, not purity
- 09:38, 25 Jan 2025 (diff | hist) Analytical method validation 4,021 ±0 add the repeatability figure with the number of injections
- 10:30, 12 Nov 2024 (diff | hist) Deamidation 2,020 ±0 m give the limit of quantitation with the signal-to-noise ratio it assumes
- 13:21, 6 Nov 2024 (diff | hist) Bacterial endotoxin test 2,929 ±0 m expand §Methods
- 03:14, 18 Oct 2024 (diff | hist) Area percent purity 3,346 +369 clarify that area percent is not mass percent
- 23:12, 16 Oct 2024 (diff | hist) High-performance liquid chromatography 4,166 +840 add the system-suitability criteria the method actually specifies
- 01:17, 12 Jul 2024 (diff | hist) Reverse-phase HPLC 2,305 +958 add the ionisation mode to the mass-spectrometry description